ABV Calculator
Enter your original gravity (OG) and final gravity (FG) from your hydrometer readings to get alcohol by volume, apparent attenuation, and an estimated calorie count.
Results
Formula used: –
Attenuation = (OG − FG) ÷ (OG − 1) × 100. Calories are estimated from real extract and alcohol by weight — close enough for planning, not lab-accurate.
How the ABV formula works
When yeast ferments sugar into alcohol and CO₂, the beer's density drops. The standard homebrew formula converts that drop into alcohol percentage: ABV = (OG − FG) × 131.25. It is simple and accurate enough for most beers under ~6% ABV.
The alternate formula — ABV = (76.08 × (OG−FG) ÷ (1.775 − OG)) × (FG ÷ 0.794) — corrects for the fact that alcohol is less dense than water, which the simple formula ignores. The two agree within a tenth of a point on a 5% pale ale but diverge on big beers, so use the alternate for barleywines and imperial stouts.
Two worked examples
A standard pale ale. OG 1.050, FG 1.010. Standard formula: (1.050 − 1.010) × 131.25 = 0.040 × 131.25 = 5.25% ABV. Apparent attenuation is (0.040 ÷ 0.050) × 100 = 80%, right in the healthy range for most ale yeasts, and the calorie estimate lands around 160 kcal per 12 oz. Nothing about those numbers should surprise you; that is the point of a baseline example.
An imperial stout, where the formulas split. OG 1.090, FG 1.022. The standard formula gives (0.068) × 131.25 = 8.9% ABV. The alternate formula gives (76.08 × 0.068 ÷ (1.775 − 1.090)) × (1.022 ÷ 0.794) = (5.173 ÷ 0.685) × 1.287 = 9.7% ABV. Nearly a full point apart, on the same readings. The standard formula quietly assumes the density drop is all sugar turning into alcohol of negligible effect on density, and that assumption gets worse as alcohol content rises. Below about 6% the two formulas agree within a tenth of a point, so use the standard for everyday beers and the alternate for anything big. Attenuation here is (0.068 ÷ 0.090) × 100 = 76%, normal for a strong beer where alcohol itself starts slowing the yeast down.
Why your ABV number might be wrong
The formulas are exact; the readings usually are not. The four errors that actually move the result:
- Reading a warm sample. Hydrometers are calibrated at a specific temperature, usually 60°F or 68°F (check yours). A sample read at 100°F can read several points low, which inflates your calculated ABV. Cool the sample or apply a temperature correction.
- Reading the top of the meniscus. Read at the liquid's surface line, at eye level, not where the liquid climbs the glass. A one or two point error here is a quarter point of phantom ABV.
- CO₂ bubbles on the hydrometer. In an active or just-finished sample, bubbles cling to the hydrometer and lift it, faking a higher gravity. Spin the hydrometer gently to shed them, or degas the sample first.
- Taking FG too early. A gravity reading is only a final gravity when it is identical across two readings taken two or three days apart. A single early reading can make a still-fermenting beer look finished, and bottling it anyway is how bottle bombs happen.
Each of these is a reading problem, not a math problem, which is why the guide to reading a hydrometer properly is worth five minutes before your next brew day.
Frequently asked questions
How do you calculate ABV from OG and FG?
The standard homebrew formula is ABV% = (OG − FG) × 131.25. For stronger beers above ~6% ABV, the alternate formula shown above is more accurate.
What is a good attenuation for beer?
Most ales land at 70–80% apparent attenuation. Below ~65% can mean a stuck fermentation; above ~85% can mean a very dry beer or contamination. See how to read a hydrometer if your numbers look off.
How many calories are in a 12 oz beer?
A typical 5% ABV 12 oz beer has roughly 150–170 calories from alcohol plus residual carbs. Stronger, sweeter beers run higher.